How Often Should a Grease Trap Be Pumped?
Key takeaways
- Two rules apply: pump at 25% of trap depth, and don’t exceed the local calendar maximum. The stricter one governs.
- Quarterly is a common backstop, but it’s set locally and published guidance disagrees about statewide rules.
- Fill rate depends on trap size against kitchen volume, covers per week, menu, and fryer use, not on size alone.
- Record depth at every service. After 3 or 4 visits you can set an interval defensible with the customer’s own numbers.
- The wrong interval costs either a wasted trip or an overflow, and measurement prevents both.
Two rules govern this, and the stricter one wins.
The first is a condition trigger: pump when floating grease and settled solids together reach 25% of the trap’s depth. The second is a calendar backstop set by the local ordinance, commonly quarterly. Whichever comes first is your answer.
Most content on this question gives you one number. That’s the part worth being careful about, because the number is local, and even published guidance disagrees about what some states require.
[image]
The 25% rule
This is the rule that describes whether a trap is still working.
A grease trap separates by letting grease float and solids settle, leaving water to pass through the middle. As the floating layer thickens and the solids build, the clear middle shrinks. At around 25% of total depth occupied, separation starts to fail and grease begins carrying into the sewer line, which is the thing the whole regulatory structure exists to prevent.
So it isn’t a maintenance preference. It’s the point at which the equipment stops doing its job.
In the field, a driver checks it with a dipstick or a sludge judge, reads both layers, and compares against total depth. It takes a minute and it’s the single most useful thing to record at every service.
The calendar backstop
Most municipal FOG programs pair the 25% trigger with a maximum interval, because a trigger nobody checks isn’t enforceable.
Quarterly is the common one. New Orleans, for example, requires pumping at least every 90 days and within 2 working days of hitting the 25% threshold. Chicago’s rules commonly require cleaning at least every 90 days. Some California cities set 6-month minimums, others 90 days, frequently with language making it explicit: whichever is more frequent.
That phrase is worth internalizing, because it resolves the apparent conflict between the two rules. They aren’t alternatives.
Why the number differs between towns
Because FOG programs are municipal. The sewer authority that has to deal with your customer’s grease sets the rules about it.
This is where published guidance gets unreliable. Researching this question turns up sources confidently stating that particular states set a single statewide frequency, and other sources saying the backstop is set locally in those same states. They can’t both be right, and the safe assumption for an operator is that your local ordinance governs.
Don’t take a number from an article, including this one. Find the ordinance where you operate and work from that. If you service traps across several municipalities, you’re working to several schedules, which is a scheduling problem before it’s a compliance problem.
What drives fill rate
Two traps of identical size on the same street can need completely different schedules.
Trap size relative to the kitchen. An undersized trap on a busy kitchen fills fast regardless of what anyone wants. This is common in older buildings and in spaces converted to restaurants.
Covers per week. The clearest proxy for volume. A place doing 200 covers and one doing 2,000 are not on the same schedule.
Menu and fryer use. A fryer-heavy kitchen loads a trap far faster than one doing mostly grilled or cold service.
Whether a grinder is in use. Food solids reaching the trap change how fast the bottom layer builds.
None of that is visible from the trap’s size on a work order, which is why the schedule has to come from measurement rather than from a table.
Setting an interval you can defend
Here’s the practical method, and it takes about three visits.
Record depth at every service: floating layer, solids layer, total depth. If the driver can record the depth at every service at the stop, you get this for free rather than as a special project.
After 3 or 4 visits on the same trap, you have a fill rate. Now the interval isn’t a guess and it isn’t a default on a contract. It’s arithmetic from that specific trap, held on the trap as a record at that address alongside its history.
That matters most when a customer pushes back. A restaurant being told they need more frequent service hears an upsell. The same restaurant shown their own trap’s measurements over four visits hears a reason. Keeping the schedule you agreed with the customer next to the data that justified it makes that conversation short.
What the wrong interval costs, both ways
Too often burns a slot you could have sold to someone else, and it gives the customer a legitimate grievance about being over-serviced. That erodes an account slowly.
Too rarely risks an overflow, a backed-up line, a violation for your customer, and the phone call that follows. It also means the trap was failing to separate for part of that interval, which is the harm the rules exist to prevent.
There’s a routing dimension too. Intervals that match reality let you build the week’s routes around traps that genuinely need doing, rather than driving to traps that weren’t ready and skipping ones that were.
Keeping it straight across a route
Three things, once you’re servicing more than a handful of traps.
An interval per trap, not per customer, because one restaurant can have more than one and they rarely fill at the same rate.
A depth reading at every service, recorded at the stop.
And work that generates itself on the interval rather than depending on anyone remembering. When you bill from the service that was completed, the record that justifies the schedule and the record that produces the invoice are the same one.
This isn’t legal advice, and FOG rules change. Confirm your local requirements with the sewer authority or health department that enforces them. For the operational side of servicing grease traps on a schedule you can defend, you can see how the pieces connect. And if you want it from people doing the work, operators talking through the grease business covers plenty of ground this article doesn’t.
FAQs
How often does a grease trap need to be pumped?
When floating grease and settled solids reach 25% of the trap’s depth, or when the local ordinance’s maximum interval is up, whichever comes first. Quarterly is a common backstop but it’s set municipally, so the only reliable answer comes from the ordinance where the trap is.
What is the 25% rule?
The point at which a trap stops separating properly. As the floating layer thickens and solids build, the clear middle shrinks, and at roughly 25% of total depth occupied, grease starts carrying through into the sewer line. It’s a performance threshold rather than a maintenance preference.
Is there a legal maximum interval between cleanings?
Usually, and it’s set by the local FOG program rather than nationally. Many programs pair the 25% trigger with a calendar limit, often quarterly, and some say explicitly that whichever is more frequent applies. Confirm it locally; sources disagree about whether particular states set statewide figures.
Why do two similar restaurants need different schedules?
Because fill rate isn’t about trap size on its own. An undersized trap on a busy kitchen fills fast whatever anyone prefers, and covers per week, menu type, fryer volume and whether a grinder is in use all change the rate. Two identical traps on the same street can genuinely need different intervals.
How do I justify a more frequent schedule to a customer?
With their own trap’s numbers. Record depth at every service, and after 3 or 4 visits you have a measured fill rate for that specific trap. A restaurant told they need more service hears an upsell; the same restaurant shown four readings from their own trap hears a reason.